Mianyang Fubang Electronic Control Equipment Co., Ltd.Mianyang · China

Industrial Rectifier Power Supply

GZD converts three-phase AC to controlled DC for electroplating, anodising, electrolysis and heating processes. Select an operating voltage/current pair and the regulation mode required by the process.

GZD equipment
GZD

DC Power for the Process

The thyristor-bridge supply supports constant-voltage or constant-current regulation, with open-loop or closed-loop control. Match the working point to the process load, including the range required during start-up and normal operation.

  • Electroplating and anodising.
  • Electrolysis processes.
  • DC heating and related process loads.

AC Supply & DC Working Point

ItemSeries selection information
AC supplyThree-phase 380 VAC ±15%, 50 Hz
DC voltage range0–1,000 VDC across the series
DC current range0–3,000 ADC across the series
Regulation modesConstant voltage / constant current; open or closed loop
Environment−25 to 40°C; relative humidity <85%

Voltage and current are paired for the selected design. The two series maxima do not mean that 1,000 V and 3,000 A can be supplied together. They must not be multiplied to claim a 3 MW standard product.

Regulation, Protection & Control

The supply includes soft start and overcurrent/overvoltage protection. Protection settings and the control arrangement are selected for the operating point and process duty.

Specify whether control is local or external and identify the signal needed by the process controller. Confirm signal range, polarity and isolation before interface design; a generic analogue-control range is not assumed.

Enclosure dimensions, cooling arrangement, wiring and applicable protection settings are confirmed in the technical proposal.

Selection Questions

Can any voltage be combined with any current in the listed ranges?

No. The ranges describe the series. The required voltage/current working point and process duty must be checked together.

Does GZD support constant-current operation?

Constant-current and constant-voltage regulation are listed. State which mode the process requires and whether an external control signal is needed.

Discuss Your Configuration

Share the information you have. A complete specification is not required for an initial enquiry.

  • Normal and maximum process voltage/current as a pair.
  • Process type, duty cycle and required CV/CC mode.
  • AC source, installation environment and control interface.

Ask for the available catalogue, drawings and technical documents for your equipment.