UPS Systems

Compare industrial, transformer-based online and high-frequency online UPS families for critical AC loads. Start with the input/output phase arrangement, load demand and required battery autonomy.

FBDU-QI / FBDU-Q / FBDU-GP equipment
Shown: FBDU-QI industrial UPS

Choose the UPS Family

FBDU-QI · Industrial UPS

For important industrial AC loads. Input/output isolation and front access support industrial installation and maintenance. The family lists IGBT/DSP control, N+X parallel operation, cold start, three-stage charging and a maintenance bypass.

FBDU-Q · Transformer-based Online UPS

For industrial, control and data loads, with rack or tower configurations. Options include 12-pulse rectification, N+1 operation, cold start and battery/charging selection.

FBDU-GP · High-frequency Online UPS

For online AC backup in rack or tower form. Features include DSP control, touchscreen status, 50/60 Hz recognition, cold start, EPO and ECO modes. Output isolation transformer availability depends on configuration.

Capacity & Phase Arrangements

Family / formatInput → outputListed capacity
FBDU-QI1-phase → 1-phase or 3-phase → 1-phase1–30 kVA
FBDU-QI3-phase → 1-phase40–120 kVA
FBDU-Q · rack1-phase → 1-phase or 3-phase → 1-phase1–20 kVA
FBDU-Q · tower1-phase → 1-phase or 3-phase → 1-phase1–30 kVA
FBDU-Q · tower3-phase → 1-phase40–120 kVA
FBDU-Q3-phase → 3-phase10–400 kVA
FBDU-GP · rack / tower1-phase → 1-phase1–10 kVA
FBDU-GP · rack / tower3-phase → 1-phase10–30 kVA
FBDU-GP · rack3-phase → 3-phase10–30 kVA
FBDU-GP · tower3-phase → 3-phase10–200 kVA

Capacity belongs to the stated family, phase arrangement and format. Confirm nominal input/output voltage and frequency for the selected model. A 400 kVA range does not apply to every FBDU family or rack configuration.

Battery, Bypass & Monitoring

  • Size the battery for the actual load and required autonomy; there is no single backup duration for all systems.
  • FBDU-QI lists a maintenance bypass. Confirm bypass arrangements for other families in the selected configuration.
  • FBDU-Q lists RS232 / RS485, Modbus and dry contacts, with SNMP available as an option.
  • FBDU-GP lists RS232 / RS485 and dry contacts, with optional SNMP. Battery string selection must be confirmed for the chosen model.

Station UPS systems that share a DC-system battery are a separate configuration. Do not apply that arrangement automatically to QI, Q or GP families. For common station supplies, see the Integrated AC/DC system.

Selection Questions

Are UPS capacities expressed in kW or kVA?

The family capacity selections on this page are in kVA. Provide load kW and power factor as well; do not treat kVA and kW as equal.

Is the battery included in every quoted UPS?

Battery type, capacity, cabinet arrangement, charging requirements and supply scope are confirmed in the configuration proposal.

Can every UPS share a station DC battery?

No. Shared-battery station UPS is a distinct arrangement. Confirm isolation, DC voltage, protection and compatibility before selecting it.

Discuss Your Configuration

Share the information you have. A complete specification is not required for an initial enquiry.

  • Load list, kW/kVA and power factor if available.
  • Input/output voltage and phase arrangement.
  • Backup duration, rack or tower space, bypass and monitoring needs.

Ask for the available catalogue, drawings and technical documents for your equipment.

Browse UPS Systems · All product families